All-In-One Sanitization Solution: If your heater comes on as a consequence of the thermostat temperature increase, it is working properly. Hayward, Create a Pool Owner If your motors electrics and bearings are constantly exposed to too much heat, then they will begin to fail. That cable doesn't affect the standby light? Find many great new & used options and get the best deals for Hayward HAXCPA1932 Control Assembly for Pool Heater H Series ED2 PARTS ONLY! Save my name, email, and website in this browser for the next time I comment. Once you have made sure there is no water damage then your next trip should be to the circuit breaker of the heater. All But, the hot or cold display wont work this time even after rebooting. This heater uses flow activation technology instead of a traditional pressure switch, which increases its reliability and reduces the risk of burnt-out switches. They come in different models and offer versatility in the power line. One of the easiest ways to clean your pool is to use a chlorine tablet. Gear-obsessed editors choose every product we review. But, first, contact a professional service technician to have them look at the pool heater. Professional Profile, View All service center location, advanced You need to look under the metal cover to the right of the transformer. Is the battery fully charged? Resetting a furnace blower motor is simple. With more information, I may be able to help with troubleshooting. Look for signs of rusting, leaking, or other damage. Otherwise there is a possible leak.Troubleshooting Guide for DIGITAL Thermostat ControlLights Run (green)No power to heat pumpTripped circuit breaker/ no power supply check breaker and ensure that the unit is properly installed.Faulty electrical componentCall HAYWARD service department for info.High / Low Pressure Switch Outside temperature too cold.Check ambient temperature, if lower than 50 DegreesUnit will not runcheck water flow to heat pump. Lighting, Learn About Comment * document.getElementById("comment").setAttribute( "id", "ac431c5de09cf2f7f65c469e877d54fe" );document.getElementById("ha302b2da6").setAttribute( "id", "comment" ); Save my name, email, and website in this browser for the next time I comment. All rights reserved. He loves to share his knowledge & helps others in fixing their units & saving their pockets. Your email address will not be published. It is being practiced by thousands of pool owners just like you. How to diagnose and repair your Hayward H Series Natural Gas Swimming Pool Heater Queb 5.99K subscribers Subscribe 368K views 8 years ago Audio turned out weird, so you may have to turn the. As far as furnace failures go, this issue has the potential to be solved easily. Just for the heck of it remove the back cover on the new board enclosure and make sure the ribbon cable from the keypad is connected. But they do require service checks from time to time. Sure, they're a major investment, but a worthwhile one, if you consider the blissful feeling of always-perfect water temperature. No real way to troubleshoot that other than replace it and see what happens. Then, you can catch any potential problems before they become significant issues. If your Hayward pool heater mode button is not working, try raising your thermostat to a temperature higher than that of your pool to see if it is operational or not. Our mission is to provide you with the absolute best how-to advice, in-depth buying guides and honest product reviews on every topic related to buying, owning and maintaining a swimming pool. Error codes show up on the digital screen of the H-Series H150, H200, H250, H300, H350, and H400 gas models. Fits hayward h-series millivolt electronic ed2 style pool heater. Selection with the Arrow Buttons. The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. Too much salt will leave your pool feeling like a swimming pool. Troubleshooting Hayward Gas Heaters Do NOT attempt to adjust or service without consulting your dealer, professional pool or air conditioning contractor. Visually checking the breaker is on is inadequate, as some switches move only a short distance when they trip. I'll check tomorrow and post a new pic. If water gets into your blower motor, you will notice corrosion on the motor casing and control panel. H400 control panel assembly replacement. If you do not have a remote device connected, call HAYWARD for service info.PST Push button stuck Release the buttonPNL Control not receiving data from panel Control Problems Call HaywardCEL Panel not receiving data fromcontrol Control Problems Call HaywardCHC Board self-check error Board Failure Call Hayward, The pool store did not sound too excited about working on it when a called about a service call and suggested a new heater for $2,300 might be a better option than repairing a six year old unit. With any luck, you may be able to pull off a successful repair all on your own. You are using an out of date browser. If the pump is running, then the water flow is normal. They hook up to the pools filter, and water absorbs the sun's heat as flows through channels inside the panels. ThePoolInsider.com. If you are unable to resolve or determine a problem, additional info can be obtained by contacting the HAYWARD Service Department.Troubleshooting Guide for MECHANICAL Thermostat ControlNo Power to UnitMake sure power is on.Breaker is thrown Check the breaker / see note above.Thermostat not turned up high enoughTurn thermostat up until unit comes on.5 minute delay timer still runningBe sure the 5 minute delay has passed.Make sure filter is cleanLow water flowMake sure filter pump is on.Unhook cleaning devices (skimmers, crawlers, etc. more, View Simply resetting wont work in this case. JavaScript is disabled. All Products, View b. at the best online prices at eBay! Maintenance. Call HAYWARD for service info.Thermostat set too highTurn thermostat down.Heat pump runs continuallyElectrical component failureTurn off the filter pump. Tips & Insights: How Does a Central AC Unit Work? Once youre sure water is running through the heater, check each valve and switch to locate the problem. Lets look at a few plausible reasons. Pumps, Learn About When the arrows are pointing in the wrong direction, change the orientation of the filter. Next, check the thermostat. Here are some of the more common issues with pool heaters: If your pool heater isnt producing heat, then the pool heater probably needs to be fixed. Pentair Water Pool and Spa, Inc. is not affiliated with Hayward Industries, Inc. nor endorses Hayward's products. Plus, the pool heaters in this list are from reputable brands, including Hayward, Raypak, and Pentair, known for quality products and customer service, so you can get the support you need if you have questions about the heater or if anything goes wrong. Any new postings here are unlikely to be seen or responded to by other members. This code means there is something wrong with the gas valve. There may be a voltage issue occurring that you didnt notice. Where are you measuring the 28 volts?? It provides heat to the water in the pool. Step 5: Take the new keypad and remove the 3m covering. If you need a new furnace motor, our team is also skilled in furnace installations. Using a larger-sized pool heater than needed could lead to overheating. We also searched for the best models for each fuel source, as well as heaters at various price points. If unplugging and plugging your fan back in again doesnt work, check the fuse box. Save my name, email, and website in this browser for the next time I comment. To check the gas valve, turn off the power, open the cover and look inside the valve. There's also a conveniently placed digital control panel. more, View A surge in electricity may have overloaded your system, and the breaker has popped. By Ann Carrns. The control panel will stop working if a breaker has been tripped due to power overload. The PL-P-4 model can control a single conventional heater (gas or heatpump). In this circumstance, the temperature will rarely exceed 65 degrees. IE9 and older versions are not supported. These two components work together to ensure that the pool heater operates correctly. There is a jumper on the board that has to be changed for 120 volt service. If you notice loose connections, tighten them immediately. If your blower fan has power, then the next step is to check the thermostat on your furnace. We recommend this unit because of its versatility, as it can be installed in new and existing pool systems. You should change or clean your pool filter every 3 months to keep your pool heater in good shape. Cleaners, Learn About Now if they are in the same position then we are back to square one. Free shipping for many products! Hayward pool heater display board not working due to defective pressure switch, circuit board issues, incorrect wirings, or faulty touchpad. Sanitization, Learn About registration, authorized Rio Bravo, Inc. I don't know of any gas valves that operate at 6V? Most thermostats will be set to auto automatically when they come from the factory. Not sure from your information exactly which version of the Hayward H series heater you have. The most common reason is heavy rain. The heater is made with a cupronickel heat exchanger that can withstand low pH, high-flow, or heavy use, plus it's certified for low NOx emissions. Step 4: After taking everything off, you should clean the whole board. Work through the chart below if your heater displays the following error codes. from Press the "Mode" button on the digital heater control panel to put the system in "Standby." Press and hold the "Up" and "Down" buttons simultaneously and wait until the indicator light and . OK.Thanks. heater or pool filtering system. Picking out a pool heater can feel like a daunting task because there are so many details to wade through. You can find a heater with an appropriate BTU output by calculating your pools surface area (multiply length by width), then dividing the number by three. For homes without a natural gas line, this pool heater from Raypak conveniently runs on liquid propane tanks. A small issue can quickly turn into something far worse. Your session is about to timeout due to inactivity. If the keypad/display is not getting DC power from the control board for some reason, it would result in no display and no heater operation. If the heater doesn't shut off, you have a faulty valve that must be replaced. This is another common problem with pool heaters. When I flip the circuit breaker I can hear a little clicking noise but nothing shows up on the control panel. If you have further queries, dont forget to let us know in the comment section. If this is a newer FD, then you have a plug that one end is 120 and the other is 240. Profile, Create a Pool Professional Some pool heaters even last up to 15 years or more! In her four years as a product tester, she's tested hundreds of items firsthand, and her work appears in publications such as Forbes, USA Today, The Spruce, Food52, and more. Is the 3A fuse on the ciruit board good?? Make sure that you inspect the pool heater once per month. These are set at the factory for 240 volt operation. Profile, Create a Pool Owner Please remove additional products. Please remove additional products. Notes - Delivery *Estimated delivery dates include seller's handling time, origin ZIP Code, destination ZIP Code and time of acceptance and will depend on shipping service selected and receipt of cleared payment. Once or twice a season should be fine unless you have hard water issues that could cause premature mineral buildup. hayward In this case, youd have to replace the whole display board. A bad capacitor will always sound more like a buzz than anything else. Step 3: Flip the display board and take out the keypad. Click OK to extend your time for an additional 0 minutes. You can reset a pool heater from the circuit breaker or control panel. Wait for warmer temperatureLoss of refrigerantCall HAYWARD service department for info.Switch failureCall HAYWARD service department for info.Fan motor failureCall HAYWARD service department for info.Coil obstructionCall HAYWARD service department for info.Perform cleaning procedures described in this manual.Air flow obstructionCall HAYWARD service department for info.LP Low Pressure SwitchCheck water flow to heat pump. thank you. You can refer to your heaters handbook to see where they belong. Or, maybe your heater isn't generating heat at all. To do so, remove the wire running between the gas valve and the thermostat. Our technicians have the tools necessary to perform a furnace repair or tune-up service at your home in Jacksonville, Florida. #1 Hello, I received a Hayward H350 heater (used) and had my pool guy hook it up. f5 is probably SF, sensor failure. There are several different ways to clean your pool. Why Is Hayward Pool Heater Control Panel Not Working? Now the standby light finally comes on, but I can't get it out of standby. The SF means sensor failure. Looking for more great ways to upgrade your pool this summer? Lighting, Learn About Ensure that the pool heater's thermostat has a higher temperature setting than the current water temperature of your pool. A pool heater usually takes 1-2 hours to work after it has been turned on. While removing it, be careful and dont press the buttons. If you have a small pool, then you probably wont need a very expensive pool heater. read more )Outside temperature too lowCheck outside ambient temperature / wait for warmer temperatures for unit to operate. Your Pool went from Clean to Green Overnight. Products, learn Sorry for the delay. Step 1: Shut the power off and then take out all the screws from the display board. This system can raise your pools temperature by as much as 10 degrees, though it only works well on sunny days. +. Hayward websites have been developed in compliance with standards for Internet Explorer 10 or later. Ok. Will try when I get home in the morning. Before you buy, youll need to consider your pool size and style (in- or above-ground), the right power source for your setup, plus whether the heaters power is enough to efficiently heat the water. However, they can be quite pricey, generally costing several thousand dollars. You need to ensure that the pool heater receives enough voltage from the electrical outlet. Pentair MasterTemp 400 - no lights on the panel and not coming on, With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. Hayward-Summit Technical Support: 800-432-8387, Check the installation of the heat pump first to assure it is installed per the installation manual. It also features an electronic ignition, as well as a wind-resistant design thats ideal for outdoor installation. The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. If water dries up then it is only condensation. LCD display is blank, and I tried all buttons (mode, up, down) for various lengths of time and combinations with no luck. Hayward, Create a Pool Owner If they don't match up to the old part you took off, then you need to set them in the same position as the old one was. training events, warranty If youre currently dealing with a broken air conditioner, an inefficient system, or you would like to schedule a routine, pre-season tune-up, Fenwick is here to help! Fenwick is your trusted name in heating services offering an unmatched level of service. That is the transformer and it only steps down the voltage to 24v. Theyre also incredibly difficult to fix.